first draft measurement for Multiple sensors setup at ~29% RH
Device/sensor | t | RH |
---|---|---|
Green Day | 22.1 | 29.4% |
Xiaomi MHO-C201 | 22.1 | 31% |
Senserion S.G. | 22.14 | 35.58% |
Beurer HM16 | 21.6 | LOW |
TFA Spring | 22.2 | 28% |
TFA t/RH | 22 | 28% |
SHT21 (1) | 22.13 | 37.56% |
SHT21 (1) | 22.21 | 38.98% |
HTU21D (1) | 22.10 | 28.39% |
HTU21D (1) | 22.39 | 28.08% |
HTU21D (2) | 22.22 | 28.14% |
SHT20 | 22.28 | 31.06% |
SHT21 (2) | 22.17 | 30.45% |
SHT25 | 22.33 | 31.17% |
SHT30 | 22.02 | 32.54% |
SHT30 | 22.09 | 33.10% |
SHT31 | 21.99 | 34.06% |
SHT31 | 21.99 | 34.11% |
SHT35 | 22.04 | 31.87% |
SHT35 | 22.14 | 31.53% |
SHT31 (2) | 22.09 | 35.21% |
SHT85 | 22.00 | 30.05% |
BME680 | 22.55 | 31.35% |
BME680 | 22.88 | 30.60% |
BME280 | 22.90 | 27.56% |
BME280 | 22.67 | 27.99% |
BME280 | 22.94 | 27.10% |
BME680 (2) | 23.74 | 25.61% |
BME680 (2) | 24.05 | 25.82% |
DHT12 | 22.10 | 22.4040% |
DHT12 | 21.90 | 34.5050% |